Subject: Disconnects please help 2003-05-14 - By freemanpc@(protected)
Back Anyone;
I have the unfortunate task of trying to solve a disconnect problem for my company. All of the cabling in brand new and tests fine. We have 3Com managed switches and a pix506e firewall.
Here is the log of one of the disconnects. I think the getty has a bug in it? Any suggestions would be appreciated.
05/13 14:43:43 147 mgetty: experimental test release 1.1.26-Apr16
05/13 14:43:43 147 check for lockfiles
05/13 14:43:43 147 locking the line
05/13 14:43:43 147 tio_get_rs232_lines: TIOCMGET failed: Invalid argument
05/13 14:43:43 147 WARNING: DCD line still active, check modem settings (AT&Dx
)
05/13 14:43:43 147 WARNING: DSR is off - modem turned off or bad cable?
05/13 14:43:43 147 lowering DTR to reset Modem
05/13 14:43:43 147 WARNING: DSR is off - modem turned off or bad cable?
05/13 14:43:43 147 lowering DTR to reset Modem
05/13 14:43:43 147 TIOCMBIC failed: Invalid argument
05/13 14:43:44 147 waiting...
05/13 14:43:47 147 tio_get_rs232_lines: TIOCMGET failed: Invalid argument
05/13 14:43:47 147 WARNING: starting login while DCD is low!
05/13 14:43:47 ##### data dev=dty0147, pid=12098, caller='none', conn='DIRECT',
name='', cmd='/bin/login', user='karla'
|
|